HI 2300Benchtop MetersAnalytical InstrumentsHome

HI 2300Back

Multi-ranging EC, TDS, NaCl, Temperature Meter with 4-ring Potentiometric Conductivity Probewith PlatinumSensors
  • Auto-ranging
  • 4-ring potentiometric conductivity probe with internal temperature sensor
  • Automatic (ATC), Manual (MTC) or No Temperature Compensation (NoTC)
  • Good Laboratory Practice
  • PC compatible
Specification
Range : (EC) 0.00 to 29.99 µS/cm; 30.0 to 299.9 µS/cm; 300 to 2999 µS/cm; 3.00 to 29.99 mS/cm; 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual EC)*
Range : (TDS) 0.00 to 14.99 mg/L (ppm); 15.0 to 149.9 mg/L (ppm); 150 to 1499 mg/L (ppm); 1.50 to 14.99 g/L (ppt); 15.0 to 100.0 g/L (ppt); up to 400.0 g/L (actual TDS)*, with 0.80 conversion factor
Range : (NaCl) 0.0 to 400.0%
Range : (Temp) -9.9 to 120.0°C
Resolution : (EC) 0.01 µS/cm; 0.1 µS/cm; 1 µS/cm; 0.01 mS/cm; 0.1 mS/cm
Resolution : (TDS) 0.01 mg/L; 0.1 mg/L; 1 mg/L; 0.01 g/L; 0.1 g/L
Resolution : (NaCl) 0.1%
Resolution : (Temp) 0.1°C
Accuracy : (EC) ±1% of reading ± (0.05 µS/cm or 1 digit)
Accuracy : (TDS) ±1% of reading ± (0.03 mg/L or 1 digit)
Accuracy : (NaCl) ±1% of reading
Accuracy : (Temp) ±0.4°C
Calibration : (EC) automatic, 1 point with 6 memorized values (84, 1413, 5000, 12880, 80000, 111800 µS/cm)
Calibration : (NaCl) 1 point, with HI 7037 calibration solution
Calibration : (Temp) 2-point, at 0 and 50°C (32 and 122°F)
Temperature Compensation : automatic or manual, 0 to 60°C (32 and 140°F)
Temperature Coefficient : selectable from 0.00 to 6.00%/°C (EC and TDS only)
TDS Conversion Factor : selectable from 0.40 to 0.80 (default value: 0.50)
Probe : (included) HI 76310, 4-ring platinum, internal temperature sensor
Auto-off : after 5 minutes of non-use (can be disabled)
Power Supply : (included) 12 Vdc adapter
Environment : 0 to 50°C (32 to 122°F); RH max 95%
Dimensions/Weightv : 240 x 182 x 74 mm / 1.1 kg

Overview

HI 2300 measures EC, TDS, NaCl and temperature. In extended conductivity and TDS ranges (up to 500 mS/cm and 400 g/L respectively) the instrument automatically chooses the best scale.

This instrument utilizes a 4-ring potentiometric probe with platinum sensors that offers greater versatility over typical amperometric designs. By utilizing the 4-ring method, it is possible to measure very low or high conductivity levels without changing probes.

Calibration is automatic at 1 point with 6 memorized buffers.

The meter has 3 options for temperature compensation: ATC between 0 to 60.0°C , MTC and NoTC.

Other features include a read lock function, stability indicator, GLP and PC compatibility via optional HI 92000 software.

Product Contents

HI 2300 is supplied with conductivity probe, power adapter and instructions.

 